Ghrian Domestic Series acts as a Mini Solar Plant which can be a primary source of electricity generation in your home, reducing your dependence on and consumption of state-supplied power. This means greater independence from unreliable electricity supply, power cuts and excessive electricity bills as the revolutionary product has been designed in a way that it recovers only the differential current from grid supply. Ghrian Home series are developed based on the idea powered with high cost performance, equipped with high stability, reliability and high practical applicability. Ghrian Home Series unit can be used in apartments, independent houses and offices which takes up 90 sqft per KW on the rooftop.
Model | GH500S/D | GH1000D | GH1500D | GH2500D |
---|---|---|---|---|
PCU Power | 500 | 1000 | 1500 | 2500 |
Solar Rated Power | 250w/500w | 1000w | 1500w | 2500w |
Communication Port | N/A | RS 232 / USB / SNMP ( Setup available for regular start/shutoff) | ||
Communication Cable | N/A | |||
Monitoring Software | N/A | |||
Working Mode | PV ( Photovoltaic Priority) / AC ( AC Priority ) Optional | |||
PV – AC transfer time | Less than 3 msec | Less than 3 msec | Less than 3 msec | Less than 3 msec |
Battery Voltage / Range | 24 Vdc / 21 – 30 Vdc | 24 Vdc / 21 – 30 Vdc | 48 Vdc / 42 – 60 Vdc | 48 Vdc / 42 – 60 Vdc |
MPPT Voltage Range | 24 Vdc – 45 Vdc | 24 Vdc – 45 Vdc | 48 Vdc – 90 Vdc | 48 Vdc – 90 Vdc |
Max Charge Current | 10A / 20A / 30A / 40A/60A | |||
Conversion Efficiency | ≥ 98 % | |||
Panel Indicator Light | LCD + LED | |||
Input Voltage Range | 230 V ± 25% | |||
Input Frequency Range | 45 – 65 Hz ( Automatically transfer to Inverter power when over frequency ) | |||
Output Voltage | 230 ± 10% | |||
Input PF ( AC/DC ) | 98.00% | |||
Charge Current | 15Amax ( PV no input current, battery ≤ 90% ) | |||
Efficiency | Mains mode ≥ 96% | |||
Mains Overload | 110% 60s to bypass power; 120% transfer to bypass power after 30s; automatically recover when decrease load | |||
Short Circuit | System Automatically Shutdown | |||
Output Frequency | 50Hz ± 1% | |||
Output PF | 0.8 | |||
Wave Form Distortion | Linear Load ≤ 5% | |||
Inverter Overload | 110% shutdown at 60s, 120% shutdown at 5s | |||
No-Load off optional | Load < 5% the system automatically shut down at 1 min, transfer to bypass power | |||
Mains abnormal | 1/4s; automatic sound elimination after 40s | |||
Low battery | 1/0.2s | |||
Over Load | 1/1s | |||
Ambient Humidity | 10 – 90% ( Non Condensed ) | |||
Noise | ≤50db | |||
Dimension | 380 x 195 x 478 | |||
Solar Cell | Poly -crystalline 156x156mm | |||
Module Dimension | 1482x992x40mm | |||
Weight | 19kg | |||
Max. System Voltage / A | 1000 v (TUV) / 600v(UL) / 15A | |||
Output Cable | PV 4mm2 | |||
Cable Length | 90cm+5 | |||
Number of bypass diodes | 6 | |||
Panel Temp cycling range | (-40-85 °C) | |||
Output Socket | Universal sockets 3 PCS / Customized | |||
IP Class | IP 21/54 | |||
Ambient Temp | 0 °C-40 °C |